Logo ICM - Industrial Control MachineICM HomeICM CompanyICM ProductsICM ServicesICM JobsICM ContactSecurity websiteSpanish version & Registered area Español Registered area
 
77 View the Control Unit

 

Site-X 180 FEATURES  (Back to list)
Download the datasheet of the Site-X 180
UNITS C1802
with CCU086
Output voltage range kV 50 to 180
Output voltage selection step kV 1
Tube current range mA 1 to 3
Tube current at full output mA 2
Tube current selection step mA 0.1
Maximum useful angle of X-ray beam (°) 360 x (2x20)
Dimensions of optical focal spot mm ø 4 x 0.5
Inherent filtration mm Equiv. 3.5 (Al)
Working cycle at 40°C ambient temp. % 100
Operating temperature range °C -25 to +70
Storage temperature range °C -40 to +80
SF6 insulation pressure at 20°C kg/cm² 5.0
Cooling fan supply voltage VDC 48
Weatherproof level - IP65
Penetration into steel at max. power (Dia=6"/D7/D=2.0/T=10s) mm Fe 11
Penetration into steel at max. power (Dia=18"/D7/D=2.0/T=1min) mm Fe 11
Guard rings no
Position of interconnection socket choice Free axial
Maximum leakage dose at 1 m mSv/h 2.5
Microcontroller HT measurement circuit (kV and mA) - yes
Overall dimensions mm ø 124 x 580
Total weight without guard rings kg 9.5
     