Logo ICM - Industrial Control MachineICM HomeICM CompanyICM ProductsICM ServicesICM JobsICM ContactSecurity websiteSpanish version & Registered area Español Registered area
 
92 View the Control Unit

 

Site-X 300 FEATURES  (Back to list)
Download the datasheet of the Site-X 300
UNITS C3003
with CCU186
Output voltage range kV 90 to 300
Output voltage selection step kV 1
Tube current range mA 1 to 5
Tube current at full output mA 3
Tube current selection step mA 0.1
Maximum useful angle of X-ray beam (°) 360 x (2x20)
Dimensions of optical focal spot mm ø 5 x 0.8
Inherent filtration mm 2.5 (Al) + 0.4 (Ni)
Carrousel of internal diaphragms with lead cap - no
Working cycle at 40°C ambient temp. % 100
Operating temperature range °C -25 to +70
Storage temperature range °C -40 to +80
SF6 insulation pressure at 20°C kg/cm² 5.0
Cooling fan supply voltage VDC 24
Weatherproof level - IP65
Penetration into steel at max. power (FFD=700mm/Film D7pb/D=1.5/T=20 min) mm Fe 54
Guard rings no
Position of interconnection socket choice Axial/Radial
Number of telescopic centring device (FFD=700mm) -
Maximum leakage dose at 1 m mSv/h 10
Microcontroller HT measurement circuit (kV and mA) - yes
Overall dimensions mm ø 248 x 757
Total weight without guard rings kg 32
     
Back

 

 

 

ICM News




Improvements to the SITE X 360
We’re glad to announce you that we improved the SITE X 360 ... Read More

 

Territories & new comers
In the present-time, we wanted to let you know that whatever... Read More

 




Subscribe to the NDT Newsletter

 

Globulebleu - www.globulebleu.com